Ademco XM/First Alert FAC Program Sheet. Enter Program 1. + 8 + 0 + 0 (Display should show 00). or. 2. Power down then back up and press. The Ademco XM is a UL Listed commercial fire and burglary control system. Its advanced integrated design is aimed at providing a powerful solution for the. ADDENDUM TO: INSTALLATION INSTRUCTIONS FOR XM CONTROL Ademco High Speed off-normal test reports use channel 3 =1 and status channel .

Author: Kagajar Mishakar
Country: Switzerland
Language: English (Spanish)
Genre: Art
Published (Last): 13 October 2009
Pages: 322
PDF File Size: 3.45 Mb
ePub File Size: 6.95 Mb
ISBN: 165-2-93605-116-6
Downloads: 56429
Price: Free* [*Free Regsitration Required]
Uploader: Fejas

When aremco short occurs on a polling loop branch, it illuminates a trouble LED and isolates the defective branch from the system— reducing troubleshooting time. The next step is to remove the panel from the cabinet. Please enter 5 or 9 numbers for the ZIP Code. A brand-new, unused, unopened and undamaged item in original retail packaging where packaging is applicable.

Ademco XM Program Sheet

Leave the earth ground wire connected during this process. Notes Under normal conditions no ground faults you should read 1. Any device wired to the control panel can cause a ground fault. Smoke Maintenance Feature When using the Smoke Detector on a panel that does not support the Maintenance feature, it must remain disabled on the detector by 51400xm dip switch 8 ON.

ADEMCO VISTA XM USER MANUAL Pdf Download.

As this progresses, you may eventually reach a point where all wires are removed except the battery and the earth ground. Find out more about your rights as a buyer – opens in a new window or tab and exceptions – opens in a new window or tab. Add to Watch list. Isolate individual devices until you have a basic subsystem that works properly. This includes panel connections, RPM connections, aademco field wiring.

Set the RPM for serial mode if it can and try to manually enroll the device. Sales tax may apply when shipping to: However, if you remove the earth ground wire, your panel may still have a connection to earth ground through the cabinet and conduit connected. If using serial devices, attempt to manually enroll the serial number.

  CONTROL NEUROMOTOR DEL HABLA PDF

Each module can individually support up to mA.

AC, auxiliary power, and battery with and without AC. Make sure that they are not backwards, that the correct chart was used, and that all dips are set correctly, including dip switch 1 and 2. Select a valid country. Edmonton, London, United Kingdom. This amount is subject to ademcl until you make payment. Email to friends Share on Facebook – opens in a new window or tab Share on Twitter – opens in a new window or tab Share on Pinterest – opens in a new window or tab.

A control panel normally reports a short on a polling loop as a trouble on zone 97 or A few panels do not have any delay on reporting a polling loop short as a trouble. Trusted seller, fast shipping, and easy returns.

As noted above, the panel mounting screws provide an adecmo path between the earth ground terminal 30 and the panel cabinet.

Total Load ma Learn More – opens in a new window or tab Any international shipping is paid in part to Pitney Bowes Inc. For standby power this range has a nominal 5 – 8 year life. If a given control panel can support a total number of devices requiring more than mA, a module may be used in the manner demonstrated in Figure 1, below.

In this case, if the cabinet is grounded or has conduit that is grounded, an earth ground fault would be sensed through the other connections to the device. Shipping cost cannot be calculated. Zone type Input type Wrong loop loop 1 must be used before loop 2, left loops must be used before right loops Wrong partition 2. Sealed Lead Acid Batteries. KP -zone – and polling loop – are all common.

This will not only tell us you have received your 51440xm, but it will also allow us to leave feedback to you to complete the transaction. Twisted or Shielded Wire with one end of the shield to ground is a must for polling loop runs. Most purchases from business sellers are protected by the Consumer Contract Regulations which give you the right to cancel the purchase within 14 days after the day you receive the item.

  JIBAN SMRITI PDF

Read more about the condition. Then troubleshoot the RPM itself.

Ademco VISTA 5140XM User Manual

Can other boards or peripherals Power supplies, LRR radios, etc cause a ground fault? A total load current of Locate the row in the table selected in step 1 corresponding to the total device load current determined in step 2. See Note 3 Below a. For additional information, see the Global Shipping Program terms and conditions – opens in a new window or tab. Ask your installer if your system was set up to allow system zones and conditions for problems such as zone wire breaks, loss of AC power, faulted telephone system outputs to be bypassed.

With this field enabled, no other polling loop devices will operate. Det ect s and i solat es polling loop br anches wit h complet e or r esist ive shor t s, and over l oad or defect ive polling l oop devices on init i al power up 2.

Report item – opens in a new window or tab. This battery comes already charged, sealed, maintenance free, and ready to install. If using Dip-Switch devices, verify that you do not have any 2 zones set for the same address.

Otherwise, operation is as described above. If you require help or are unsure if this battery is right for you, please email or call us on before you purchase. The maximum number of V-plex device loading that can be placed 1540xm one or more polling loops with a single supporting control panel is mA.